  1.  
  2. ============================================================================
  3.  
  4.                                   IMPORTANT.
  5.                                   ----------
  6.  
  7.  THIS PROJECT IS UNDER DEVELOPEMENT AND WILL HOPEFULLY BE READY FOR 1-4-2002.
  8.  
  9. ============================================================================
  10.  
  11.  
  12.                   A Standard Single Channel Data Logger.
  13.                   --------------------------------------
  14.  
  15.   Technical Specifications:-
  16.   --------------------------
  17.  
  18.   1) Number Of Channels...........  1, Single Ended only.
  19.   2) Calibrated Sensitivity.......  2 Volts peak to peak, centred around
  20.                                     0 Volts.
  21.   3) Input Impedance..............  Better than 10 KilOhms.
  22.   4) Coupling.....................  DC Only. External Capacitor needed to
  23.                                     make the unit AC Coupled.
  24.   5) Resolution...................  20 mV.
  25.   6) Accuracy.....................  + or - 20 mV.
  26.   7) DC Stability.................  + or - 3 Vertical Pixels.
  27.   8) Temperature Stability........  + or - 3 Vertical Pixels.
  28.   9) Sampling Speeds..............  1 Pixel/10 Seconds to 10 Pixels/Second,
  29.                                     in 3 ranges.
  30.  10) Data Save Facility...........  Yes, this is automatic but can be
  31.                                     disabled and is from a 512 Byte buffer,
  32.                                     that is NOT user accessible.
  33.  11) Ability To Load Data.........  Yes, 1 x 512 Byte buffer at a time.
  34.  12) Printing Capability..........  No.
  35.  13) Maximum Safe Input Volts.....  5 Volts peak to peak.
  36.  14) Input Protection.............  NONE, be very careful of Over Voltage
  37.                                     on the input.
  38.  15) PP3 Battery Life.............  Better than 5 Hours.
  39.  
  40. ============================================================================
  41.  
  42.   Acknowledgements:-
  43.   ------------------
  44.  
  45. First of all many thanks to my wife Tricia who allows me to spend many hours
  46. on my computers.
  47.  
  48. Also to David Benn and Herbert Breuer for the ACE/AIDE combination supplied
  49. on an AMIGA FORMAT floppy disk which made it easy to compile this program.
  50.  
  51. And finally to anyone else who I may have neglected or forgotten.
  52.  
  53. ----------------------------------------------------------------------------
  54.  
  55.     Mr Barry Walker,
  56.     70 King George Road,
  57.     Loughborough,
  58.     Leicestershire,
  59.     LE11 2PA,
  60.     England.
  61.  
  62.     Email to:-
  63.  
  64.     wisecracker@tesco.net
  65.  